Tru-D (Total-Room Ultraviolet Disinfector)
The Tru-D is ideal for surface disinfection in laboratories, operating suites, ICU, clinics, schools, high risk areas, and any highly susceptible surface. The primary benefit is 3 to 6 log surface disinfection of entire area. The secondary benefit is airborne microbial disinfection and VOC removal within the space.
Construction
Rugged, stainless steel, aluminum, and injection-molded polymer construction- All units feature advanced shock-resistant CPU’s, calibrated UV sensor arrays, and solid-state electronics to insure rugged, long-term reliability
- Portable and easy to move with locking non-scar rubber casters and removable handle
- Removable hard case protects the TRU-D unit and lamps during transportation and storage
- Hard case cover includes remote-control storage and signage to act as an entry barrier during use
- 1540 nominal watts / 504 UV watts to exceed all microbial disinfection requirements
- Advance PureVolt® Solid state electronic UV ballasts are perfectly matched with twenty-eight (28) environmentally-friendly low-mercury Philips high-output twin-tube UV SteriLamps® for reliability, efficiency and germicidal effectiveness. 1250 inches of UV tube arc length. 9000 hour lamp life
- Simple 120V, 15A plug-and-go operation
- Enclosed dimensions = 69” H x 27” W, 158 lbs.
Process
- Disinfect an entire room with one portable, easy-to-use, self-monitoring device
- Position the TRU-D near the center of the room; activate the UV cleansing energy disinfection process from outside the area using a wireless remote
- Removable, hard-case lamp and storage protectors serve as warning signage to prevent accidental exposure
- Once activated, an array of sensors measure the germicidal UV-C energy reflected back to the unit
- An onboard CPU calculates the time required to effectively provide 3 to 6 log disinfection to all shaded areas within the room. Progress information is displayed on the wireless remote
- Door sensors deactivate the unit if people attempt to enter a room during the disinfection process
- The TRU-D automatically powers down when the preferred germicidal disinfection rate is achieved
- 3 to 6 log air and surface decontamination is achieved in 20-30 minutes, depending upon the degree of decontamination required and the area size and configuration of the area to be decontaminated
- The disinfected area is ready for immediate occupation and use.
Related Articles
- Acinetobacter Baumanii vs UVC (PDF) Download Now
- Tru-D Anthrax Trial (PDF) Download Now
(Requires Acrobat Reader)
Ordering Information
Item Number |
Length (with handle) |
Height |
Width |
Nominal Watts |
UV-C Watts |
Lamps (included) |
Lamp Hours |
TRU-D |
27” |
69” |
27” |
1540 |
504 |
(28) PL-L TUV 55W |
9000 |